Customers reviews

Products

Professional PRCD-S ADVANCED mobile personal protection circuit-breaker Professional PRCD-S ADVANCED mobile personal protection circuit-breaker
Professional PRCD-S ADVANCED mobile personal protection circuit-breaker Professional PRCD-S ADVANCED mobile personal protection circuit-breaker
Professional PRCD-S ADVANCED mobile personal protection circuit-breaker
For professional use on construction sites and outdoors, the PRCD-S ADVANCED mobile personal protection circuit breaker from offers a reliable and robust solution to protect the user when using...

Item number

T2g-RB 43479

€ 250,00 *
€ 151,25 *
Quantity: 
Order
 
Wishlist

Do you have a question about this product?

Ask us your question

For professional use on construction sites and outdoors, the PRCD-S ADVANCED mobile personal protection circuit breaker from offers a reliable and robust solution to protect the user when using electrical appliances on sockets that are not known to be working properly. Cables with a connection cross-section of 1.5mm² or 2.5mm² and a cable diameter of 8-14mm can be connected. Safety is further increased thanks to improved testing for protective conductor interruption from approx. 1kO, glove detection (device cannot be switched on in the event of a fault even with insulating gloves) and the comprehensive function test by checking the entire signal chain from protective conductor monitoring to the RCD switching function. The mobile personal protection system also impresses with the following features:

* Protection class: IP55
* Rated voltage: 230V
* Rated current: 16A
* Rated power: 3680W
* Rated residual current: I?n = 30mA
* All-pole (L/N/PE) switching residual current circuit breaker type A
* Undervoltage tripping
* No automatic restart after voltage recovery
* No switching on if the protective conductor is interrupted or energised
* As soon as voltage occurs on the protective conductor during operation or the protective conductor is interrupted, the protective device switches off
* If external voltage occurs on the protective conductor, e.g. by drilling into a line of another circuit, the protective device does not disconnect the protective conductor
* For use on construction sites in accordance with DGUV 203-006 (formerly BGI 608) and permanent outdoor use
* PRCD in accordance with VDE 0661
* Category 2 equipment (K2 DGUV 203-005): Use for rough operation with high mechanical, physical and chemical impacts

Ask a question about this product

Fields marked with a * are mandatory

Your question has been sent! Thank you.

We will provide you with an answer as soon as possible.